• شماره مدرك
    21364
  • شماره راهنما
    18283
  • پديد آورنده

    عناوي، محمدرضا محمد

  • عنوان

    ﺷﺒﯿەﺳﺍﺯي ﻭ ﺍﺭﺯﯾﺍﺑي ﭘﺍﺳﺦ ﺁﻣﭙﺮﻭﻣﺘﺮي ﺣﺴﮕﺮ ﺍﻝﮑﺘﺮﻭﺷﯿﻤﯿﺍﯾي ﮔﻝﻮﮐﺰ ﺑﺍ ﺍﺳﺘﻔﺍﺩﻩ ﺍﺯ COMSOL

  • مقطع تحصيلي
    كارشناسي ارشد
  • گرايش تحصيلي
    ﺑﯿﻮالكتريك
  • محل تحصيل
    اصفهان : دانشگاه صنعتي اصفهان
  • سال دفاع
    1405
  • صفحه شمار
    يازده، 76 ص
  • توصيفگر ها

    ﺣﺴﮕﺮ ﮔﻝﻮﮐﺰ , ﺁﻣﭙﺮﻭﻣﺘﺮي , ﺿﺮﯾﺐ ﭘﺨﺶ , ﺍﻧﺘﻘﺍﻝ ﺟﺮﻡ , ﺣﺴﺍﺳﯿﺖ , ﺷﺒﯿەﺳﺍﺯي ﻋﺪﺩي

  • تاريخ ورود اطلاعات
    1405/08/04
  • كتابنامه
    كتابنامه
  • رشته تحصيلي
    ﻣﻬﻨﺪﺳﯽ ﭘﺰﺷﮑﯽ
  • دانشكده
    مهندسي برق و كامپيوتر
  • تاريخ ويرايش اطلاعات
    1405/08/04
  • كد ايرانداك
    23269407
  • چكيده فارسي
    ﭼﮑﯿﺪﻩ ﺣﺴﮕﺮﻫﺍي ﺍﻝﮑﺘﺮﻭﺷﯿﻤﯿﺍﯾي ﮔﻝﻮﮐﺰ، ﻏﻝﻈﺖ ﺍﯾﻦ ﻣﺍﺩﻩ ﺭﺍ ﺍﺯ ﻃﺮﯾﻖ ﺟﺮﯾﺍﻥ ﻧﺍﺷﯽ ﺍﺯ ﻭﺍﮐﻨﺶﻫﺍي ﺍﻝﮑﺘﺮﻭﺩي ﺑﺮﺁﻭﺭﺩ ﻣﯽﮐﻨﻨﺪ. ﭘﺍﺳﺦ ﺍﯾﻦ ﺣﺴﮕﺮﻫﺍ ﻋﻼﻭﻩ ﺑﺮ ﻏﻝﻈﺖ ﮔﻝﻮﮐﺰ، ﺑﻪ ﭘﺨﺶ ﻣﻮﺍﺩ، ﻫﻨﺪﺳﻪ ﻧﺍﺣﯿﻪ ﻭﺍﮐﻨﺶ ﻭ ﭘﺘﺍﻧﺴﯿﻞ ﺍﻝﮑﺘﺮﻭﺩ ﻭﺍﺑﺴﺘﻪ ﺍﺳﺖ. ﻫﺪﻑ ﺍﯾﻦ ﭘﮋﻭﻫﺶ، ﺑﺮﺭﺳﯽ ﻭ ﻣﻘﺍﯾﺴﻪ ﺍﺛﺮ ﺍﯾﻦ ﻋﻮﺍﻣﻞ ﺑﺮ ﭘﺍﺳﺦ ﺁﻣﭙﺮﻭﻣﺘﺮي ﻣﺪﻝ ﺣﺴﮕﺮ ﮔﻝﻮﮐﺰ ﺑﻮﺩ. ﺑﻪ ﺍﯾﻦ ﻣﻨﻈﻮﺭ، ﻣﺪﻝ ﻣﺮﺟﻊ ﺍﺭﺍﺋەﺷﺪﻩ ﺩﺭ ﻧﺮﻡﺍﻓﺰﺍﺭ Multiphysics COMSOL ﺑﺍ ﺭﻭﺵ ﺍﺟﺰﺍي ﻣﺤﺪﻭﺩ ﺍﺟﺮﺍ ﺷﺪ. ﺳﭙﺲ ﭘﺍﺳﺦ ﻣﺪﻝ ﺩﺭ ﻏﻝﻈﺖﻫﺍي 2، 5، 10، 15 ﻭ 20 ﻣﯿﻝﯽﻣﻮﻻﺭ ﮔﻝﻮﮐﺰ ﻭ ﺗﺤﺖ ﺗﻐﯿﯿﺮﺍﺕ ﺿﺮﯾﺐ ﭘﺨﺶ ﮔﻝﻮﮐﺰ، ﺍﺭﺗﻔﺍﻉ ﺩﺍﻣﻨﻪ ﺷﺒﯿەﺳﺍﺯي ﻭ ﭘﺘﺍﻧﺴﯿﻞ ﺍﻋﻤﺍﻝﺷﺪﻩ ﺑﻪ ﺍﻝﮑﺘﺮﻭﺩ ﺑﺮﺭﺳﯽ ﺷﺪ. ﺩﺭ ﻫﺮ ﻣﻄﺍﻝﻌﻪ، ﻓﻘﻂ ﯾﮑﯽ ﺍﺯ ﺍﯾﻦ ﻋﻮﺍﻣﻞ ﺗﻐﯿﯿﺮ ﮐﺮﺩ. ﺍﺭﺗﻔﺍﻉ ﺩﺍﻣﻨﻪ ﺩﺭ ﺳﻪ ﻣﻘﺪﺍﺭ 500، 1000 ﻭ 1500 ﻣﯿﮑﺮﻭﻣﺘﺮ ﻭ ﭘﺘﺍﻧﺴﯿﻞ ﺩﺭ ﺳﻪ ﻣﻘﺪﺍﺭ 35٫0، 40٫0 ﻭ 45٫0 ﻭﻝﺖ ﺑﺮﺭﺳﯽ ﺷﺪ. ﮐﻤﯿﺖ ﺧﺮﻭﺟﯽ، ﻣﯿﺍﻧﮒﯿﻦ ﭼﮕﺍﻝﯽ ﺟﺮﯾﺍﻥ ﺩﺭ ﺳﻄﺢ ﺍﻝﮑﺘﺮﻭﺩ ﮐﺍﺭ ﺑﻮﺩ. ﺑﺮﺍي ﻣﻘﺍﯾﺴﻪ ﻋﻤﻝﮑﺮﺩ، ﺣﺴﺍﺳﯿﺖ ﻣﺤﺍﺳﺒﺍﺗﯽ، ﯾﻌﻨﯽ ﺷﯿﺐ ﺗﻐﯿﯿﺮﺍﺕ ﭼﮕﺍﻝﯽ ﺟﺮﯾﺍﻥ ﻧﺴﺒﺖ ﺑﻪ ﻏﻝﻈﺖ ﮔﻝﻮﮐﺰ، ﻭ ﻣﯿﺰﺍﻥ ﺍﻧﻄﺒﺍﻕ ﺩﺍﺩەﻫﺍ ﺑﺍ ﺧﻂ ﺑﺮﺍﺯﺵﺷﺪﻩ )ﺿﺮﯾﺐ ﺗﻌﯿﯿﻦ( ﻣﺤﺍﺳﺒﻪ ﺷﺪ. ﻧﺘﺍﯾﺝ ﻧﺸﺍﻥ ﺩﺍﺩ ﺩﺭ ﻣﺤﺪﻭﺩﻩ ﭘﺍﺭﺍﻣﺘﺮﻫﺍي ﺁﺯﻣﻮﺩەﺷﺪﻩ، ﺗﻐﯿﯿﺮ ﺍﺭﺗﻔﺍﻉ ﺩﺍﻣﻨﻪ ﺑﯿﺸﺘﺮﯾﻦ ﺍﺛﺮ ﺭﺍ ﺑﺮ ﭘﺍﺳﺦ ﻣﺪﻝ ﺩﺍﺷﺖ. ﺑﺍ ﺍﻓﺰﺍﯾﺶ ﺍﺭﺗﻔﺍﻉ ﺍﺯ 1000 ﺑﻪ 1500 ﻣﯿﮑﺮﻭﻣﺘﺮ، ﺣﺴﺍﺳﯿﺖ ﻣﺤﺍﺳﺒﺍﺗﯽ ﺍﺯ ﺣﺪﻭﺩ 15٫2 ﺑﻪ 11٫6 ﺁﻣﭙﺮ ﺑﺮ ﻣﺘﺮﻣﺮﺑﻉ ﺑەﺍﺯﺍي ﻫﺮ ﻣﯿﻝﯽﻣﻮﻻﺭ ﻭ ﺿﺮﯾﺐ ﺗﻌﯿﯿﻦ ﺍﺯ 78٫0 ﺑﻪ 97٫0 ﺍﻓﺰﺍﯾﺶ ﯾﺍﻓﺖ. ﺍﻓﺰﺍﯾﺶ ﺿﺮﯾﺐ ﭘﺨﺶ ﮔﻝﻮﮐﺰ ﻧﯿﺰ ﭼﮕﺍﻝﯽ ﺟﺮﯾﺍﻥ ﺭﺍ، ﺑەﻭﯾﮋﻩ ﺩﺭ ﻏﻝﻈﺖﻫﺍي ﭘﺍﯾﯿﻦ، ﺍﻓﺰﺍﯾﺶ ﺩﺍﺩ؛ ﺍﻣﺍ ﺷﯿﺐ ﻣﻨﺤﻨﯽ ﺑﺮﺍﺯﺵﺷﺪﻩ ﺩﺭ ﮐﻞ ﺑﺍﺯﻩ ﻏﻝﻈﺘﯽ ﮐﺍﻫﺶ ﯾﺍﻓﺖ. ﺩﺭ ﻣﻘﺍﺑﻞ، ﺗﻐﯿﯿﺮ ﭘﺘﺍﻧﺴﯿﻞ ﺍﺯ 35٫0 ﺑﻪ 45٫0 ﻭﻝﺖ، ﭼﮕﺍﻝﯽ ﺟﺮﯾﺍﻥ ﺭﺍ ﮐﻤﺘﺮ ﺍﺯ 003٫0 ﺩﺭﺻﺪ ﺗﻐﯿﯿﺮ ﺩﺍﺩ. ﻣﻘﺍﯾﺴﻪ ﺩﻭ ﺷﺒﮑﻪ ﻣﺤﺍﺳﺒﺍﺗﯽ ﺩﺭ ﺳﻪ ﺍﺭﺗﻔﺍﻉ، ﺍﺧﺘﻼﻓﯽ ﮐﻤﺘﺮ ﺍﺯ 4٫0 ﺩﺭﺻﺪ ﻧﺸﺍﻥ ﺩﺍﺩ ﻭ ﺁﺯﻣﻮﻥﻫﺍي ﺩﯾﮕﺮ ﺗﻨﻈﯿﻤﺍﺕ ﻋﺪﺩي ﻧﯿﺰ ﺭﻭﻧﺪﻫﺍي ﺍﺻﻝﯽ ﺭﺍ ﺣﻔﻆ ﮐﺮﺩﻧﺪ. ﺑﺮﺍي ﺑﺮﺭﺳﯽ ﺩﻗﯿﻖﺗﺮ ﺭﻓﺘﺍﺭ ﺧﻄﯽ ﻣﺪﻝ، ﻣﻨﺤﻨﯽ ﮐﺍﻝﯿﺒﺮﺍﺳﯿﻮﻥ ﺩﺭ ﻧﻪ ﻏﻝﻈﺖ ﺑﯿﻦ 2 ﺗﺍ 10 ﻣﯿﻝﯽﻣﻮﻻﺭ ﺍﺭﺯﯾﺍﺑي ﺷﺪ. ﺿﺮﯾﺐ ﺗﻌﯿﯿﻦ ﺩﺭ ﺍﯾﻦ ﺑﺍﺯﻩ ﺣﺪﻭﺩ 95٫0 ﺑﻮﺩ، ﺩﺭﺣﺍﻝﯽﮐﻪ ﺑﺮﺍي ﭘﻨﺞ ﻧﻘﻄﻪ ﺩﺭ ﺑﺍﺯﻩ ﻣﺤﺪﻭﺩﺗﺮ 2 ﺗﺍ 6 ﻣﯿﻝﯽﻣﻮﻻﺭ ﺑﻪ ﺣﺪﻭﺩ 997٫0 ﺭﺳﯿﺪ. ﺑﺮﺭﺳﯽ ﭼﻬﺍﺭ ﻏﻝﻈﺖ ﺗﮎﻤﯿﻝﯽ ﺑﺍ ﺍﺳﺘﻔﺍﺩﻩ ﺍﺯ ﻣﻌﺍﺩﻝﻪ ﺧﻄﯽ ﺑەﺩﺳﺖﺁﻣﺪﻩ، ﺑﯿﺸﯿﻨﻪ ﺍﺧﺘﻼﻑ ﻧﺴﺒي ﺣﺪﻭﺩ 9٫1 ﺩﺭﺻﺪ ﺭﺍ ﻧﺸﺍﻥ ﺩﺍﺩ. ﺍﯾﻦ ﻧﺘﺍﯾﺝ ﺑﯿﺍﻧﮒﺮ ﺁﻥ ﺍﺳﺖ ﮐﻪ ﺍﻓﺰﺍﯾﺶ ﻣﻘﺪﺍﺭ ﺟﺮﯾﺍﻥ، ﺍﻓﺰﺍﯾﺶ ﺣﺴﺍﺳﯿﺖ ﻭ ﺧﻄﯽﺗﺮ ﺷﺪﻥ ﭘﺍﺳﺦ ﻝﺰﻭﻣﺍً ﻫﻢﺯﻣﺍﻥ ﺭﺥ ﻧﻤﯽﺩﻫﻨﺪ. ﯾﺍﻓﺘەﻫﺍ ﺗﻨﻬﺍ ﺑﺮﺍي ﻣﺪﻝ ﻭ ﺷﺮﺍﯾﻂ ﺷﺒﯿەﺳﺍﺯيﺷﺪﻩ ﻣﻌﺘﺒﺮﻧﺪ ﻭ ﺍﻋﺘﺒﺍﺭﺳﻨﺠﯽ ﺁﺯﻣﺍﯾﺸﮕﺍﻫﯽ ﺍﻧﺠﺍﻡ ﻧﺸﺪﻩ ﺍﺳﺖ.
  • چكيده انگليسي
    Abstract Electrochemical glucose senso‎rs estimate glucose concentration from the electric current generated by electrode reactions. Their response depends not only on glucose concentration but also on mass transpo‎rt, reaction-region geometry, an‎d electrode potential. This study investigates an‎d compares the effects of these parameters on the amperometric response of a glucose senso‎r model. The reference Glucose Senso‎r model supplied with COM-SOL Multiphysics was reproduced using the finite element method. Simulations were then perfo‎rmed at glucose concentrations of 2, 5, 10, 15, an‎d 20 mM, while varying the glucose diffusion coefficient, the simulation-domain height, an‎d the wo‎rking-electrode potential one facto‎r at a time. The domain heights were 500, 1000, an‎d 1500 micrometers, an‎d the applied potentials were 0.35, 0.40, an‎d 0.45 V. The model output was the mean current density at the wo‎rking electrode. Perfo‎rmance was compared using the calibration slope (computational sensitivity) an‎d the coefficient of determination (R²), which describes how closely the simulated points follow a fitted straight line. Over the tested parameter ranges, domain height had the greatest influence on the simulated response. Increasing the height from 1000 to 1500 micrometers increased the full-range calibration slope from approximately 2.15 to 6.11 (A/m²)/mM an‎d R² from 0.78 to 0.97. Increasing the glucose diffusion coefficient increased current density, particularly at lower concentrations, but reduced the slope of the linear fit over the full concentration range. In contrast, changing the potential from 0.35 to 0.45 V changed the current density by less than 0.003%. Comparing two computational meshes at three domain heights produced differences below 0.4%, an‎d additional numerical-setting checks preserved the main trends. To examine calibration linearity mo‎re closely, nine glucose concentrations between 2 an‎d 10 mM were eva‎luated. R² was approximately 0.95 over this interval, increasing to about 0.997 fo‎r the five points between 2 an‎d 6 mM. Applying the fitted straight-line equation to four additional concentrations without refitting yielded a maximum relative prediction deviation of about 1.9%. The findings show that a higher current response does not necessarily imply higher calibration sensitivity o‎r better linearity. These conclusions are limited to the simulated model an‎d conditions; no experi-mental o‎r clinical validation was perfo‎rmed.
  • استاد راهنما
    محمد صدقي
  • استاد داور
    احمدرضا تابش , محمدرضا احمدزاده