پديد آورنده :
نجاتي، منصور
عنوان :
كاهش آرتيفكت هاي ناشي از حركت در تصاوير آنژيوگرافي تفريق ديجيتالي با استفاده از تكنيك هاي ثبت تصوير
مقطع تحصيلي :
كارشناسي ارشد
محل تحصيل :
اصفهان: دانشگاه صنعتي اصفهان، دانشكده برق و كامپيوتر
صفحه شمار :
[هشت]،99ص.:مصور،جدول،نمودار
يادداشت :
ص.ع.به فارسي و انگليسي
استاد راهنما :
سعيد صدري، رسول امير فتاحي
توصيفگر ها :
آرتيفكت هاي حركتي , تطبيق الگو , سنجه شباهت
تاريخ نمايه سازي :
1/3/89
دانشكده :
مهندسي برق و كامپيوتر
چكيده فارسي :
به فارسي و انگليسي: قابل رويت در نسخه ديجيتالي
چكيده انگليسي :
Reduction of Motion Artifacts in Digital Subtraction Angiography Using Image Registration Techniques Mansour Nejati m nejati@ec iut ac ir Date of Submission 2010 03 09 Department of Electrical and Computer Engineering Isfahan University of Technology Isfahan 84156 83111 Iran Degree M Sc Language Persian Supervisors S Sadri sadri@cc iut ac ir and R Amirfattahi fattahi@cc iut ac ir Abstract In clinical practice digital subtraction angiography DSA is a powerful technique for the visualization of blood vessels in a sequence of X ray images With this technique a sequence of 2D digital X ray projection images is acquired to show the passage of injected contrast material through the vessels of interest In the images that show opacified vessels often referred to as contrast images background structures are largely removed by subtracting an image acquired prior to injection called the mask image The major problem encountered in DSA images is the presence of motion artifacts which arise from the misalignment of mask image and contrast images in the sequence and reduce the diagnostic value of DSA images To cope with this problem registration of the mask and contrast images is required prior to subtracting the images Image registration is the process of spatially aligning two images of the same scene taken at different times from different viewpoints and or by different sensors During the past thirty years enormous efforts have been spent on this subject and great progresses have been achieved However because of the factors such as complicated non rigid motion of the tissues inside human body and local dissimilarities caused by contrasted vessels registration of angiographic images especially coronary angiographic images concerned angiographic images in this thesis is very difficult Most of image registration techniques that have been developed for application in DSA are point based techniques In these techniques the registration process is carried out in three steps selection of a set control point from mask or contrast image calculation of displacement of selected control points and warping of mask image In this thesis these steps are studied in details and after that performance of three registration algorithms evaluated experimentally Then two new approaches to the registration of digital angiography images are proposed First proposed approach is a point based registration method in which control points are selected using Harris corner detector and edge based method and entropy is exploited as similarity measure in template matching that for reducing the computational cost of template matching procedure a hill climbing approach is used for optimization The final correction is performed by warping of mask image using the multilevel B spline interpolation function In the second proposed registration method a multiresolution search strategy and least squares optimization are used The experimental results show that the proposed methods outperform the previously presented DSA image registration approaches particularly first method that is very fast and reduces motion artifacts in DSA images effectively Key Words Digital subtraction angiography image registration motion artifacts template matching similarity measure
استاد راهنما :
سعيد صدري، رسول امير فتاحي