پديد آورنده :
شيرواني، ندا
عنوان :
اندازه گيري 1و 4- دي اكسان در سديم لوريل اترسولفات و شامپو با استفاده از تكنيك ريز استخراج با قطره حلال در فضاي فوقاني همراه با كروماتوگرافي گازي- آشكار ساز يونش شعله اي
مقطع تحصيلي :
كارشناسي ارشد
گرايش تحصيلي :
شيمي تجزيه
محل تحصيل :
اصفهان: دانشگاه صنعتي اصفهان، دانشكده شيمي
صفحه شمار :
سيزده،78ص.: مصور،جدول،نمودار
يادداشت :
ص.ع.به فارسي و انگليسي
استاد راهنما :
محمد سراجي
تاريخ نمايه سازي :
10/2/90
استاد داور :
علي اصغر انصافي، بهزاد رضايي
چكيده فارسي :
به فارسي و انگليسي: قابل رويت در نسخه ديجيتالي
چكيده انگليسي :
Determination of 1 4 dioxane in sodium lauryl ether sulfate and shampoo using headspace single drop microextraction followed by gas chromatography flame ionisation detection Neda Shirvani chemnsh@gmail com December 26 2010 Department of Chemistry Isfahan University of Technologhy Isfahan 84156 83111 Iran Degree M Sc Language Farsi Supervisor Assoc Prof Mohammad Saraji saraji@cc iut ac ir Abstract 1 4 dioxane is a by product in the production of alcohol ethoxylated surfactants that are widely used in hygienic and cosmetic products 1 4 dioxane has been considered as possible carcinogen to humans and affect on liver kidneys and the central nervous system Because of its effects the amount of 1 4 dioxane is strictly controlled in hygienic and cosmetic products So the determination of 1 4 dioxane present in these products is very important In this study headspace single drop microextraction gas chromatography flame ionisation detection was used for quantitative analysis of 1 4 dioxane in surfactant and shampoo A magnetic stirring bar and 2 0 g of NaCl were introduced in a 20 mL glass vial with a screw cap After closing the cap 8 0 mL sample solution was added by a 10 0 mL syringe and the vial was placed on a magnetic stirrer Sample solution was in equilibrium with it s headspace for 10 minutes Then needle of a 10 0 L GC syringe containing 2 0 L organic solvent methyl benzoate was passed through the silicon septum and the solvent microdrop was exposed to the headspace After extraction microdrop was withdrawn into the syringe The syringe needle was removed from the vial and the sample was injected into the GC The effective parameters on the method performance such as solvent type salt addition drop volume stirring rate equilibrium time extraction time and temperature of sample solution were studied and optimized The best extraction efficiency was achieved using methyl benzoate as the solvent and 2 0 L drop volume 900 rpm stirring rate 2 0 g NaCl 10 minutes equilibrium time 10 minutes extraction time at room temperature The linear range limit of detection and relative standard deviation were found 0 5 100 mg L 1 0 4 mg L 1 and 7 2 n 5 respectively Finally this method was applied for analysis of real samples such as sodium lauryl ether sulfate sodium lauryl sulfate different brand of shampoos hand washing and dish washing liquids Key words Headspace single drop microextraction gas chromatography surfactant dioxane shampoo
استاد راهنما :
محمد سراجي
استاد داور :
علي اصغر انصافي، بهزاد رضايي