شماره مدرك :
6410
شماره راهنما :
5984
پديد آورنده :
عرب زاده، نادره
عنوان :

طراحي و ساخت منبع يونيزاسيون الكتروسپري تقويت شدهبا گاز مه پاشي ﴿يون اسپري﴾ با هدف آناليز كمي مستقيم پروتين ها به روش اسپكترومتري تحرك يوني

مقطع تحصيلي :
كارشناسي ارشد
گرايش تحصيلي :
شيمي تجزيه
محل تحصيل :
اصفهان: دانشگاه صنعتي اصفهان، دانشكده شيمي
سال دفاع :
1390
صفحه شمار :
چهارده،81ص.: جدول، نمودار
يادداشت :
ص.ع.به فارسي و انگليسي
استاد راهنما :
تقي خياميان
توصيفگر ها :
پروتئين اصلي , انسولين , سرم آلبومين گاوي , سرم آلبومين انساني
تاريخ نمايه سازي :
23/9/90
استاد داور :
علي اصغر انصافي، محمد تقي جعفري
دانشكده :
شيمي
كد ايرانداك :
ID5984
چكيده فارسي :
به فارسي و انگليسي: قابل رويت در نسخه ديجيتالي
چكيده انگليسي :
Design and Construct Pneumatically Assisted Electrospray Ion Spray for Ion Mobility Spectrometry to Analyze Intact Proteins Nadereh Arabzadeh n arabzadeh@ch iut ac ir Date of Submission Department of Chemistry Isfahan University of Technology Isfahan Iran Degree M Sc Language Farsi Prof T Khayamian Email Taghi@cc iut ac irAbstract In this thesis the quantitative analysis of intact proteins using ion mobility spectrometry was introduced for the first time Also Pneumatically assisted electrospray Ion Spray ionization source for using in the ion mobility spectrometer was designed and Constructed In the proteomics studies after recognition of proteins measurement of their concentration is of great importance There are two significant methods for quantitative analyses of proteins One of them intact protein analysis without their transformation into peptides and the other is digestion of proteins to their peptide composers followed by their measurement In this thesis the first method was used for quantitative analyses of insulin protein with relatively low molecular weight about Dalton and albumin protein as bovin serum albumin and human serum albumin with high molecular weight about Dalton Mobile phase flow rate and nebulizing gas flow rate parameters were optimized in order to achieve the highest response sensitivity In the analysis of each one of these proteins a mixture of water and methanol was used as solvent and mobile phase Then pH of each one of these solutions was decreased about unit below the isoelectric pH of proteins using acetic acid not only for better solubility but also for having capability of analysis in the positive mode of ion mobility spectrometer Initially insulin was considered Ion mobility spectrum was compared with electrospray and ion spray ionization source and results clearly showed the effect of nebulizing gas in the ion spray on the signal intensities This significant increase is due to formation of very small aerosols of big clusters from proteins together with solvent in the presence of nitrogen nebulizing gas Existing of multiply charged states was demonstrated by comparison of two dimensional mass and ion mobility spectra reported in the papers The values of reduced mobility resulting from insulin verifies the presence of and states that it is because of protonable amino acids in insulin protein Then quantitative analysis of insulin was performed under optimized ion spray condition In each case ion mobility spectra was recorded from its appearance to obscurity Then with using Matlab software averaging the spectra was performed background correction was carried out and the integral of area below the peak was recorded as instrument response In the case of insulin linear range was M and detection limit was M Two additional proteins were analyzed similarly The influence of nebulizer gas in these two proteins which their molecular weights are higher than insulin was more clearly The linear range of bovin serum albumin was M and its detection limit was M and in the case of human serum albumin linear range was M and detection limit
استاد راهنما :
تقي خياميان
استاد داور :
علي اصغر انصافي، محمد تقي جعفري