شماره مدرك
21404
شماره راهنما
18318
پديد آورنده
سلحشوري، سمانه
عنوان
بررسي صلاحيت سرويسدهي و تخمين عمر باقيمانده مخازن ذخيره گاز CNG
مقطع تحصيلي
كارشناسي ارشد
گرايش تحصيلي
شناسايي و انتخاب مواد مهندسي
محل تحصيل
اصفهان : دانشگاه صنعتي اصفهان
سال دفاع
1404
صفحه شمار
دوازده، 85ص. :مصور، جدول، نمودار
توصيفگر ها
ارزيابي صلاحيت سرويس دهي , تخمين عمر باقي مانده , ترك , خستگي , عمر باقيمانده , كاهش ضخامت موضعي , گاز طبيعي فشرده , مخازن ذخيره
تاريخ ورود اطلاعات
1405/08/10
كتابنامه
كتابنامه
رشته تحصيلي
مهندسي مواد و متالورژي
دانشكده
مهندسي مواد
تاريخ ويرايش اطلاعات
1405/08/27
كد ايرانداك
23237682
چكيده فارسي
ﻳﻜﻲ از راهﻫﺎي دﺳﺘﻴﺎﺑﻲ ﺑﻪ اﻓﺰاﻳﺶ اﻳﻤﻨﻲ در ﺻﻨﺎﻳﻊ ﺣﺴﺎس، ﺑﺮرﺳﻲ ﺻﻼﺣﻴﺖ ﺳﺮوﻳﺲ دﻫﻲ ﺗﺠﻬﻴﺰات ﺗﺤﺖ ﻓﺸﺎر ﻫﻤﭽﻮن ﻣﺨﺎزن ذﺧﻴﺮه اﺳﺖ، زﻳﺮا ﺗﺠﻬﻴﺰات ﺗﺤﺖ ﻓﺸﺎر در ﺻﻮرت ﻣﻮاﺟﻬﻪ ﺑﺎ ﻣﻜﺎﻧﻴﺰم ﻫﺎي ﺗﺨﺮﻳﺐ ﻫﻤﭽﻮن ﺧﺴﺘﮕﻲ و ﻧﺰدﻳﻚ ﺷﺪن ﺑﻪ ﭘﺎﻳﺎن ﻋﻤﺮ ﺑﻬﺮه ﺑﺮداري، ازﺟﻤﻠﻪ ﺗﺠﻬﻴﺰات ﺧﻄﺮﻧﺎك ﻣﺤﺴﻮب ﻣﻲﺷﻮﻧﺪ. ﺑﺎ اﺳﺘﻔﺎده از روش ارزﻳﺎﺑﻲ ﺻﻼﺣﻴﺖ ﺳﺮوﻳﺲ دﻫﻲ ﻣﻲﺗﻮان ﻛﺎراﻳﻲ و ﻋﻤﺮ ﺑﺎﻗﻴﻤﺎﻧﺪه ﺳﺮوﻳﺲدﻫﻲ ﻣﺨﺎزن را اﻓﺰاﻳﺶ داد و از ﺗﻌﻮﻳﺾ زود ﻫﻨﮕﺎم آﻧﻬﺎ ﺟﻠﻮﮔﻴﺮي ﻧﻤﻮد. در اﻳﻦ ﭘﮋوﻫﺶ و در ﻗﺪم اول، ﺑﺎ اﺳﺘﻔﺎده از آزﻣﻮنﻫﺎي ﻣﺨﺘﻠﻒ، ﻧﺘﺎﻳﺞ ﻣﻄﺎﻟﻌﺎت آزﻣﺎﻳﺸﮕﺎﻫﻲ اﺳﺘﺨﺮاج ﺷﺪ. ﺳﭙﺲ ﺣﻀﻮر ﺧﺴﺘﮕﻲ، ﺗﺮك و ﻛﺎﻫﺶ ﺿﺨﺎﻣﺖ ﺑﻪﻋﻨﻮان ﻋﻮاﻣﻞ ﻣﻬﻢ ﺗﺨﺮﻳﺐ ﻣﺨﺎزن ذﺧﻴﺮه ﮔﺎز ﻃﺒﻴﻌﻲ ﻓﺸﺮده ﺑﺎ اﺳﺘﻔﺎده از ﺷﺒﻴﻪﺳﺎزي اﻟﻤﺎن ﻣﺤﺪود و دادهﻫﺎي آزﻣﺎﻳﺸﮕﺎﻫﻲ ﻣﻮرد ﺑﺮرﺳﻲ ﻗﺮارﮔﺮﻓﺖ. در اﻳﻦ راﺳﺘﺎ، ﺗﺎﺛﻴﺮ ﻋﻴﻮب ﻣﺬﻛﻮر ﺑﺮ ﻋﻤﺮ ﺑﺎﻗﻲﻣﺎﻧﺪه ﻣﺨﺎزن ﺑﺎ اﺳﺘﻔﺎده از روشﻫﺎي ﺷﺒﻴﻪﺳﺎزي اﻟﻤﺎن ﻣﺤﺪود ارزﻳﺎﺑﻲ ﺷﺪ و در ﻃﻲ اﻳﻦ ﺑﺮرﺳﻲ ﻣﺸﺨﺺ ﺷﺪ ﻛﻪ ﻣﺨﺎزن ذﺧﻴﺮه در ﺣﺎﻟﺖ ﺳﺎﻟﻢ و در ﻓﺸﺎر ﻛﺎري 30 ﻣﮕﺎﭘﺎﺳﻜﺎل ﻗﺎدر ﺑﻪ ﺗﺤﻤﻞ ﺑﻴﺶ از 2400 ﺳﻴﻜﻞ ﺑﺎرﮔﺬاري ﭼﺮﺧﻪاي ﻫﺴﺘﻨﺪ. در ﺣﺎﻟﻲ ﻛﻪ ﺣﻀﻮر ﺗﺮك ﻣﻨﺠﺮ ﺑﻪ از دﺳﺖ رﻓﺘﻦ ﻛﺎﻣﻞ ﺻﻼﺣﻴﺖ ﺳﺮوﻳﺲدﻫﻲ ﻣﺨﺎزن و وﻗﻮع ﺷﻜﺴﺖ در ﻣﺮاﺣﻞ اﺑﺘﺪاﻳﻲ ﺑﺎرﮔﺬاري ﻣﻲﺷﻮد، ﺑﻄﻮريﻛﻪ با وجودﻛﺎﻫﺶ ﺿﺨﺎﻣﺖ ﻣﻮﺿﻌﻲ، ﺣﺘﻲ ﺑﺎ ﻛﺎﻫﺶ ﻓﺸﺎر ﻛﺎري ﺗﺎ 25 ﻣﮕﺎﭘﺎﺳﻜﺎل، ﻋﻤﺮ ﺧﺴﺘﮕﻲ ﻣﺨﺰن ﺑﻪ 11 ﺳﻴﻜﻞ ﻣﺤﺪود ﻣﻲﮔﺮدد. ﭘﺲ از ﺣﺼﻮل ﻧﺘﺎﻳﺞ ﺷﺒﻴﻪﺳﺎزي، اﻋﺘﺒﺎرﺳﻨﺠﻲ دادهﻫﺎ و ﻧﺘﺎﻳﺞ آن ﺑﻪ ﻛﻤﻚ ﻣﻄﺎﻟﻌﺎت آزﻣﺎﻳﺸﮕﺎﻫﻲ ﺻﻮرت ﮔﺮﻓﺖ و ﺗﻄﺎﺑﻖ آنﻫﺎ ﺗﺎﻳﻴﺪ ﮔﺮدﻳﺪ. در اداﻣﻪ ﺑﺎ اﺳﺘﻔﺎده از ارزﻳﺎﺑﻲ ﺻﻼﺣﻴﺖ ﺳﺮوﻳﺲدﻫﻲ، ﺗﺨﻤﻴﻦ ﻋﻤﺮ ﻣﺨﺎزن ذﺧﻴﺮه ﮔﺎز ﻃﺒﻴﻌﻲ ﻓﺸﺮده ﻣﻮرد ﺑﺮررﺳﻲ ﻗﺮارﮔﺮﻓﺖ ﻛﻪ ﻧﺘﺎﻳﺞ ﻧﺸﺎن داد ﺣﻀﻮر ﺗﺮك و ﻛﺎﻫﺶ ﺿﺨﺎﻣﺖ ﻣﻮﺿﻌﻲ ﻋﻤﺮ ﺑﺎﻗﻲﻣﺎﻧﺪه اﻳﻦ ﻣﺨﺎزن را ﺑﻪ ﺻﻮرت ﻗﺎﺑﻞ ﻣﻼﺣﻈﻪاي ﻛﺎﻫﺶ ﻣﻲدﻫﺪ. اﮔﺮﭼﻪ ﻣﺨﺎزن در ﺣﺎﻟﺖ ﺳﺎﻟﻢ از ﻗﺎﺑﻠﻴﺖ ﺑﺎﻻﻳﻲ ﺑﺮاي ﺳﺮوﻳﺲدﻫﻲ ﺑﺮﺧﻮردارﻧﺪ، اﻣﺎ ﻧﻪ ﺗﻨﻬﺎ ﺑﺎ ﺣﻀﻮر ﺗﺮك ﻗﺎﺑﻠﻴﺖ ﺳﺮوﻳﺲدﻫﻲ ﻧﺪارﻧﺪ، ﺑﻠﻜﻪ اﺳﺘﻔﺎده از آنﻫﺎ در ﺻﻮرت ﺣﻀﻮرﻛﺎﻫﺶ ﺿﺨﺎﻣﺖ ﻣﻮﺿﻌﻲ، ﻣﻨﻮط ﺑﻪ ﻛﺎﻫﺶ ﻓﺸﺎر ﻛﺎري ﺗﺎ ﺣﺪود 20 ﻣﮕﺎﭘﺎﺳﻜﺎل ﻳﺎ ﻛﻤﺘﺮ از آن ﻣﻲﺑﺎﺷﺪ.
چكيده انگليسي
One of the primary methods for enhancing safety in critical industries is the serviceability qualification of pressure vessels, such as storage tanks. Pressure vessels, when subjected to degradation mechanisms such as fatigue and approaching the end of their operational life, are considered among the most hazardous types of equipment. By employing serviceability qualification methods, the performance and remaining service life of these vessels can be optimized, thereby preventing premature replacement. In this study, the first step involved conducting various experimental tests to gather laboratory data. Subsequently, the presence of fatigue, cracks, and thickness reduction, which are significant degradation factors, was investigated in compressed natural gas (CNG) storage tanks through finite element simulation and experimental data. The impact of these defects on the remaining life of the tanks was then assessed using finite element modeling. The results revealed that, in their intact state and under an operating pressure of 30 MPa, the tanks could withstand more than 2400 cycles of cyclic loading. However, the presence of cracks led to a complete loss of serviceability and caused failure during the early stages of loading. Furthermore, localized thickness reduction significantly reduced the fatigue life, even when the operating pressure was reduced to 25 MPa, limiting the fatigue life of the tank to only 11 cycles. After obtaining the simulation results, data validation was performed through experimental studies, confirming the consistency of the findings. Subsequently, the remaining service life of the CNG storage tanks was evaluated using serviceability qualification methods. The results indicated that the presence of cracks and localized thickness reduction drastically reduced the remaining service life of the tanks. While the tanks exhibited high serviceability when intact, they could no longer maintain serviceability in the presence of cracks, and the use of these tanks with localized thickness reduction required reducing the operating pressure to approximately 20 MPa or lower.
استاد راهنما
عبدالمجيد اسلامي , فخرالدين اشرفي زاده
استاد مشاور
نويد سعيدي
استاد داور
ابوذر طاهري زاده , عباس بهرامي